Data for: Restitution Characteristics of His Bundle and Working Myocardium in Isolated Rabbit Hearts
- Description:
- The Purkinje system (PS) and the His bundle have been recently implicated as an important driver of the rapid activation rate after 1-2 minutes of ventricular fibrillation (VF). It is unknown whether activations during VF propagate through the His-Purkinje system to other portions of the the working myocardium (WM). Little is known about restitution characteristic differences between the His bundle and working myocardium at short cycle lengths. In this study, rabbit hearts (n=9) were isolated, Langendorff- perfused, and electromechanically uncoupled with blebbistatin (10 μM). Pacing pulses were delivered directly to the His bundle. By using standard glass microelectrodes, action potentials duration (APD) from the His bundle and WM were obtained simultaneously over a wide range of stimulation cycle lengths (CL). The global F-test indicated that the two restitution curves of the His bundle and the WM are statistically significantly different (P<0.05). Also, the APD of the His bundle was significantly shorter than that of WM throughout the whole pacing course (P<0.001). The CL at which alternans developed in the His bundle vs. the WM were shorter for the His bundle (134.2±13.1ms vs. 148.3±13.3ms, P<0.01) and 2:1 block developed at a shorter CL in the His bundle than in WM (130.0±10.0 vs. 145.6±14.2ms, P<0.01). The His bundle APD was significantly shorter than that of WM under both slow and rapid pacing rates, which suggest that there may be an excitable gap during VF and that the His bundle may conduct wavefronts from one bundle branch to the other at short cycle lengths and during VF.
- Keyword:
- ventricular fibrillation, action potential duration, cardiology, working myocardium, rabbit, restitution curve, alternans, His bundle, and microelectrode
- Subject:
- ventricular fibrillation, cardiology, and myocardium
- Creator:
- Huang, Shangwei, Panitchob, Nuttanont, Hu, Nan, Ranjan, Ravi, Huang, Liqun, and Dosdall, Derek
- Owner:
- BRIAN MCBRIDE
- Based Near Label Tesim:
- Salt Lake City, Utah, United States
- Language:
- English
- Date Uploaded:
- 07/10/2019
- Date Modified:
- 04/18/2024
- Date Created:
- 2016-03-21 to 2016-05-25
- License:
- CCO – As the data author, you are choosing to place your data into the public domain.
- Resource Type:
- Dataset
- Identifier:
- https://doi.org/10.7278/S50R9MJX
-
- Description:
- The objective of using the wireless sensors was to improve understanding of the heterogeneity of healthcare worker (HCW) contact with patients and the physical environment in patients’ rooms. The framework and design were based on contact networks with a) nodes defined by HCW’s, rooms, and items in the room and b) edges defined by HCW’s in the room, near the bed, and touching items. Nodes had characteristics of HCW role and room number. Edges had characteristics of day, start time, and duration. Thus, patterns and heterogeneity could be understood within contexts of time, space, roles, and patient characteristics. At the University of Utah Hospital Cardiovascular ICU (CVICU), a 20-bed unit, we collected data for 54 days. HCW contact with patients was measured using wireless sensors to capture time spent in patient rooms as well as time spent near the patient bed. HCW contact with the physical environment was measured using wireless sensors on the following items in patient rooms: door, sink, toilet, over-bed table, keyboard, vital signs monitor touchscreen, and cart. HCW’s clipped a sensor to their clothing or lanyard. This dataset contains cleaned sensor pings of RFD reads between healthcare worker worn sensors and environmental sensors placed in facility using methods described in the "Data Cleaning Steps" section.
- Keyword:
- patient contact and wireless sensors
- Subject:
- cardiology
- Creator:
- Rubin, Michael, Haroldsen, Candace, and Leecaster, Molly
- Contributor:
- Huber, Tavis and Stratford, Kristina
- Owner:
- Michael Rubin
- Based Near Label Tesim:
- Salt Lake City, Utah, United States
- Language:
- English
- Date Uploaded:
- 12/26/2023
- Date Modified:
- 01/04/2024
- Date Created:
- 2018
- License:
- CC BY NC - Allows others to use and share your data non-commercially and with attribution.
- Resource Type:
- Dataset
- Identifier:
- www.doi.org/10.7278/S50d-twbh-955q
-
- Description:
- This dataset accompanies the research article entitled, "Etiology-Specific Remodeling in Ventricular Tissue of Heart Failure Patients and its Implications for Computational Modeling of Electrical Conduction," where we quantified fibrosis and performed electrophysiological simulation to investigate electrical propagation in etiologically varied heart failure tissue samples. Included are raw confocal microscopic images, data for extracting and processing the raw images and script to analyze fibrosis and generate meshes for simulation.
- Keyword:
- human, heart failure, cardiac, confocal microscopic images, simulation, and fibrosis
- Subject:
- cardiology
- Creator:
- Drakos, Stavros G., Sachse, Frank B., Kyriakopoulos, Christos P., Bragard, Jean, Greiner, Joachim, Chakkalakkal Sankarankutty, Aparna, Visker, Joseph R., and Shankar, Thirupura S.
- Owner:
- Aparna Sankarankutty
- Based Near Label Tesim:
- Salt Lake City, Utah, United States
- Language:
- English
- Date Uploaded:
- 06/08/2021
- Date Modified:
- 12/08/2023
- Date Created:
- 2019-01-01 to 2020-11-30
- License:
- CC BY NC - Allows others to use and share your data non-commercially and with attribution.
- Resource Type:
- Dataset
- Identifier:
- https://doi.org/10.7278/S50D-BPS8-R06S
-
- Description:
- The objective of using the wireless sensors was to improve understanding of the heterogeneity of healthcare worker (HCW) contact with patients and the physical environment in patients’ rooms. The framework and design were based on contact networks with a) nodes defined by HCW’s, rooms, and items in the room and b) edges defined by HCW’s in the room, near the bed, and touching items. Nodes had characteristics of HCW role and room number. Edges had characteristics of day, start time, and duration. Thus, patterns and heterogeneity could be understood within contexts of time, space, roles, and patient characteristics. At the University of Utah Hospital Cardiovascular ICU (CVICU), a 20-bed unit, we collected data for 54 days. HCW contact with patients was measured using wireless sensors to capture time spent in patient rooms as well as time spent near the patient bed. HCW contact with the physical environment was measured using wireless sensors on the following items in patient rooms: door, sink, toilet, over-bed table, keyboard, vital signs monitor touchscreen, and cart. HCW’s clipped a sensor to their clothing or lanyard.
- Keyword:
- wireless sensors and patient contact
- Subject:
- cardiology
- Creator:
- Rubin, Michael, Haroldsen, Candace, and Leecaster, Molly
- Owner:
- Michael Rubin
- Based Near Label Tesim:
- Salt Lake City, Utah, United States
- Language:
- English
- Date Uploaded:
- 05/23/2023
- Date Modified:
- 11/28/2023
- Date Created:
- 2018-03-01 to 2018-04-28
- License:
- CC BY NC - Allows others to use and share your data non-commercially and with attribution.
- Resource Type:
- Dataset
- Identifier:
- https://doi.org/10.7278/S50d-acm8-epwg
-
- Description:
- Localization of the components of the cardiac conduction system (CCS) is essential for many therapeutic procedures in cardiac surgery and interventional cardiology. While histological studies provided fundamental insights into CCS localization, this information is incomplete and difficult to translate to aid in intraprocedural localization. To advance our understanding of CCS localization, we set out to establish a framework for quantifying nodal region morphology. Using this framework, we quantitatively analyzed the sinoatrial node (SAN) and atrioventricular node (AVN) in ovine with menstrual age ranging from 4.4 to 58.3 months. In particular, we studied the SAN and AVN in relation to the epicardial and endocardial surfaces, respectively. Using anatomical landmarks, we excised the nodes and adjacent tissues, sectioned those at a thickness of 4 µm at 100 µm intervals, and applied Masson’s trichrome stain to the sections. These sections were then imaged, segmented to identify nodal tissue, and analyzed to quantify nodal depth and superficial tissue composition. The minimal SAN depth ranged between 20 and 926 µm. AVN minimal depth ranged between 59 and 1192 µm in the AVN extension region, 49 and 980 µm for the compact node, and 148 and 888 µm for the transition to His Bundle region. Using a logarithmic regression model, we found that minimal depth increased logarithmically with age for the AVN (R2=0.818, P=0.002). Also, the myocardial overlay of the AVN was heterogeneous within different regions and decreased with increasing age. Age associated alterations of SAN minimal depth were insignificant. Our study presents examples of characteristic tissue patterns superficial to the AVN and within the SAN. We suggest that the presented framework provides quantitative information for CCS localization. Our studies indicate that procedural methods and localization approaches in regions near the AVN should account for the age of patients in cardiac surgery and interventional cardiology.
- Subject:
- cardiology and physiology
- Creator:
- Frank Sachse, Brian K. Cottle, and Jordan Johnson
- Owner:
- Frank Sachse
- Language:
- English
- Date Uploaded:
- 11/13/2019
- Date Modified:
- 05/17/2023
- Date Created:
- 2018
- Resource Type:
- Dataset
- Identifier:
- https://doi.org/doi:10.7278/S50D-546S-4RVW
-
- Description:
- Light-scattering spectroscopy (LSS) is an established optical approach for nondestructive characterization of biological tissues. Here, we investigated the capabilities of LSS and convolutional neural networks (CNNs) to quantitatively characterize the composition and arrangement of cardiac tissues. We assembled tissue constructs from 200 μm thick sections of fixed myocardium and aortic wall. Thickness of the tissue constructs was similar to the thickness of atrial free wall. In the assembled constructs, the aortic sections represented fibrotic tissue and the depth, volume fraction, and arrangement of these fibrotic insets were varied. We gathered spectra with wavelengths from 500-1100 nm from the constructs at multiple locations relative to a light source. We used single and combinations of two spectra for training of CNNs. With independently measured spectra, we assessed the accuracy of the trained CNNs for classification of tissue constructs from single spectra and combined spectra. In general, classification accuracy with single spectra was smaller than with combined spectra. Combined spectra including spectra from fibers distal from the illumination fiber typically yielded a higher accuracy than proximal single collection fibers. Maximal classification accuracy of depth detection, volume fraction and permutated arrangements was (mean±stddev) 88.97±2.49%, 76.33±1.51% and 84.25±1.88%, respectively. Our studies demonstrate the reliability of quantitative characterization of tissue composition and arrangements using a combination of LSS and CNNs. Potential clinical applications of the developed approach include intraoperative quantification and mapping of atrial fibrosis as well as assessment of ablation lesions.
- Subject:
- cardiology
- Creator:
- Hitchcock, Robert W., Sachse, Frank B., Cottle, Brian K., Kelson, Bailey E.B., and Knighton, Nathan J.
- Owner:
- Frank Sachse
- Based Near Label Tesim:
- Salt Lake City, Utah, United States
- Language:
- English
- Date Uploaded:
- 01/09/2020
- Date Modified:
- 01/22/2022
- Date Created:
- 20190101 to 20190208 and 20200721 to 20200807
- Resource Type:
- Dataset
- Identifier:
- https://doi.org/10.7278/S50D-3Q4J-SC4Y